INSTITUTE OF ELECTRONICS 
 "ACADEMICIAN EMIL DJAKOV" 
 BULGARIAN
 ACADEMY
 OF SCIENCES
INSTITUTE OF ELECTRONICS
 "ACADEMICIAN EMIL DJAKOV" 
 BULGARIAN
 ACADEMY
 OF SCIENCES
INSTITUTE OF ELECTRONICS
"ACADEMICIAN EMIL DJAKOV"

 BULGARIAN
 ACADEMY
 OF SCIENCES


LABORATORY
"BIOPHOTONICS"





PROJECT: KP06/COST/16

„Identification of diagnostically relevant biomarkers in tear fluids using optical methods“

Procedure for providing national co-funding for the participation of Bulgarian research teams in approved Actions under the European Cooperation in Science and Technology (COST) Programme



Head of the Bulgarian team:  Assist. Prof. Dr. Aleksandra Zhelyazkova




 PROJECT SUMMARY:

Tear fluid is a promising non-invasive source of diagnostic information. It naturally contains proteins, lipids, metabolites, electrolytes, and other molecules that may reflect both ophthalmic and systemic diseases. Tear fluid can be collected for research purposes without invasive intervention, while enabling the detection of diagnostically significant biomarkers.

One of the most promising optical diagnostic methods is fluorescence spectroscopy, since many tear fluid components exhibit autofluorescence. Disease-related changes in protein composition, oxidative stress, and metabolic status are reflected in the intensity and shape of their fluorescence spectra. In addition, the application of synchronous fluorescence spectroscopy provides improved resolution and enables the identification of fluorescence maxima in biological samples containing multiple fluorophores, such as tears. In practice, this method makes it possible to distinguish overlapping fluorescence maxima and to better define spectral changes of biochemical origin. The project aims to identify diagnostically significant biomarkers in tear fluid using optical methods. The project team has extensive experience in the application of fluorescence techniques, including the analysis of biological samples and the identification of diagnostically significant optical biomarkers, which will be utilized in the forthcoming studies of tear fluid.

A complementary approach is Raman spectroscopy, which enables the acquisition of a molecular “fingerprint” and detailed biochemical information on tear fluid composition. In addition, the method does not require sample pretreatment, and the effects of water molecules are negligible compared with other techniques, which is advantageous because tears are an aqueous biofluid.

Other optical methods in which the team has longstanding experience in the study of biological samples include polarimetry, fluorescence microscopy, and polarization microscopy. The benefits of applying these methods to the investigation and analysis of tear fluid for diagnostically significant biomarkers will be identified within the project.

The main limitation to the application of optical methods for tear fluid analysis is not their analytical potential, but their clinical implementation. Before they can be used routinely in clinical settings, protocols must be developed for reproducible tear collection, standardized sample pretreatment, and reliable analysis. This necessitates the establishment of a database covering common and significant diseases. Nevertheless, studies to date support tear fluid spectroscopy as an emerging field for the early detection, monitoring, and assessment of treatment in conditions such as dry eye syndrome, glaucoma, diabetes, and other diseases.



 RESEARCH TEAM:

Bulgarian team:
/Institute of Electronics/

  • Assist. Prof. Dr. Aleksandra Zhelyazkova (Team Leader)
  • Assist. Prof. Dr. Tsanislava Genova
  • Assist. Prof. Dr. Liliya Angelova
  • Physicist Viktoria Mircheva

 WORK PACKAGES:

Work Package 1:

Selection and collection of samples. Development of a protocol for tear fluid analysis.

Aim: To obtain experimental samples of “simulated tears”, i.e., solutions that mimic the composition of human tear fluid. Standardized protocols will be developed for collecting tear fluid from volunteers under strictly controlled conditions, in order to minimize external influences and ensure reproducibility of the results. The collection, selection, and classification of samples from patients with different pathologies will be coordinated with COST Action partners, in compliance with ethical and regulatory requirements. In parallel, a systematic literature review will be conducted to develop validated protocols for spectral and microscopic examination of tear fluid. Particular attention will be paid to identifying sensitive approaches for detecting biomarkers associated with ocular and systemic diseases.


Work Package 2:

Preparation of the experimental setup and samples for spectroscopic measurements.

Aim: The selected samples will be carefully prepared in accordance with established standards and the developed protocols, in order to minimize the risk of contamination and reduce artifacts associated with sample preparation. Controlled storage and handling procedures will be implemented to ensure the stability of their physicochemical properties until analysis.

Experimental setups for the planned spectral measurements will be prepared, and their functionality will be tested.

Precise calibration, verification, optimization, and preparation of the experimental setups for spectroscopic and microscopic measurements will be carried out. Initial measurements will help identify key measurement parameters and potential sources of systematic error, thereby enabling the development of a detailed and reproducible protocol. Optimal parameters for subsequent spectral and microscopic measurements will be established.


Work Package 3:

Autofluorescence measurements of all tear fluid samples.

Aim: Autofluorescence measurements will be performed under strictly controlled and constant excitation and fluorescence-signal acquisition conditions, in order to optimize the signal-to-noise ratio and minimize background and unwanted effects. Fluorescence excitation–emission matrices will be recorded over an appropriate spectral range, selected according to the spectral characteristics of the main fluorophores in tear fluid. The data will subsequently undergo spectral analysis to evaluate fluorescence intensities, maxima, and spectral shapes, and to identify significant differences between individual samples.


Work Package 4:

Raman measurements of all tear fluid samples.

Aim: Raman measurements will be performed using carefully selected excitation wavelengths, chosen to minimize the background signal and optimize spectral intensity. The experiments will be conducted under controlled and constant conditions, including optimization of the exposure time and the number of accumulated spectra, in order to improve the signal-to-noise ratio and prevent sample degradation. The acquired spectra will be processed and normalized, followed by a detailed analysis of the characteristic Raman bands to identify the sample components.


Work Package 5:

Processing of the obtained results and detailed analysis.

Aim: Autofluorescence spectral data will be acquired using high-sensitivity spectrofluorometric instrumentation under strictly controlled and reproducible excitation and emission conditions, in order to optimize the signal-to-noise ratio and minimize background effects. Fluorescence excitation–emission matrices will be recorded over an appropriate spectral range, selected according to the characteristic fluorophores in tear fluid. Raman measurements will be performed using an optimized excitation wavelength, while controlling parameters such as exposure time and the number of accumulations, in order to improve spectral quality and prevent sample degradation. The acquired spectra will undergo preprocessing and subsequent analysis to identify characteristic spectral features. Microscopic images will be obtained following precise sample preparation under controlled conditions that ensure preservation of the natural morphology. Image data will be processed using specialized software, including segmentation, extraction of morphological descriptors, and analysis of texture characteristics. Finally, comparative and statistical methods will be applied for the integrated analysis of spectral and morphological data, with the aim of identifying diagnostically significant biomarkers.


Work Package 6:

Acquisition of microscopic images of tear fluid. Analysis of microscopic images.

Aim: Sample preparation and microscopic image acquisition will be carried out under strictly controlled conditions to preserve the natural morphology and spatial distribution of the components. Appropriate sample preparation techniques will be used, including control of temperature, humidity, and the method of sample deposition on the substrate. Images will be acquired using optimized microscopy parameters (magnification, illumination, and contrast) appropriate to the sample type. The resulting data will be processed using specialized image-analysis software, including segmentation, extraction of morphological descriptors, and assessment of texture characteristics. Quantitative methods will be applied to evaluate the size, shape, and distribution of the observed structures, along with statistical approaches to compare different samples.


Work Package 7:

Statistical assessment of sensitivity and specificity for diagnostic purposes, based on the optimized set of significant biomarkers for detecting various diseases.

Aim: Statistical processing will include the application of appropriate methods for assessing diagnostic performance, such as sensitivity, specificity, and diagnostic accuracy analyses. The data will be normalized and classified in advance. Both univariate and multivariate statistical approaches will be used to assess the significance of the selected biomarkers. The models will be validated using appropriate techniques. The results will be interpreted to determine optimal diagnostic thresholds and evaluate their applicability for detecting various diseases.


 FOR MORE INFORMATION:

https://www.cost.eu/actions/CA24112/
https://www.tear-precision.eu






Copyright © 2026, Institute of Electronics, BAS